The difference between a ball valve and a check valve is who does the work. With a ball valve, you do: turn the lever and the line opens or shuts. With a check valve, the fluid does. Forward flow pushes it open, and the moment flow stops or tries to run backwards, it closes on its own. One is a tap. The other is a one-way gate.
What does a ball valve do?
A ball valve is a quarter-turn isolation valve. A sphere with a hole bored through it sits between two seats. Turn the lever 90 degrees and the bore lines up with the pipe and flow passes straight through. Turn it back and the solid side of the ball blocks the line. Pressed against soft seats, a good ball valve closes bubble-tight.
That makes it the default isolation valve in Australian industry, on everything from compressed air drops and chemical dosing lines to mine dewatering pipework and fuel systems. It opens and closes fast and seals in both directions.
Common ball valve types include one-piece and two-piece bodies at the budget end, three-piece bodies that unbolt in the middle so seats can be replaced in the line, flanged versions for larger bolted pipework, and three-way L-port and T-port valves that divert or mix flow. Full bore versions have a hole the same size as the pipe; reduced bore versions are one size smaller and cheaper.
What a ball valve is not is a control valve. Leave a standard ball valve half open and high-velocity flow past the edge of the ball chews out the seats. It is built to be fully open or fully shut. A stainless steel ball valve from our ball valve range starts at $11.87 inc. GST.
What does a check valve do?
A check valve, also called a non-return valve, lets fluid flow one way only. There is no handle. Forward flow pushes a disc, plug or ball off its seat and holds it open. When the pump stops, or pressure downstream rises above pressure upstream, the disc drops back onto the seat and the line is closed. Nobody has to be there.
There are four common types.
- Swing check. A hinged disc swings open with flow and falls closed by gravity. Cheap and low pressure drop, but it needs horizontal or upward vertical flow to close properly, and it can slam. A hinged disc swings open with flow and falls closed by gravity. Low pressure drop and cheap, but it needs horizontal or upward vertical flow to close properly, and it can slam.
- Lift check. A plug or piston lifts vertically off the seat. Good for high pressure and gas, but orientation-specific. A plug or piston lifts vertically off the seat. Good for high pressure and gas, but only works in the orientation it was designed for.
- Dual plate wafer. Two spring-loaded half discs close fast and fit between flanges in a very short face-to-face. This is the usual pick for pump discharge where water hammer is a risk (our 316 stainless dual plate wafer check starts at $92.30 inc. GST).
- Ball check. A free ball rolls off a seat under forward flow and rolls back under reverse flow. Simple, tolerant of dirty water and light slurry, and common on sewage and sump pumps (see our cast iron ball check valve).
Our check valve range covers all four from DN15 to DN600, in cast iron, ductile iron, carbon steel, 316 stainless, bronze and PVC, with prices from $19.30 inc. GST.
Ball valve vs check valve: the key differences
Side by side, the contrast is sharp.
- Operation. A ball valve is operated by a person or an actuator. A check valve operates itself, driven by flow and pressure.
- Flow direction. A ball valve seals in both directions and passes flow in both directions. A check valve passes flow one way and blocks the other.
- Job. A ball valve isolates. A check valve protects against backflow.
- Orientation. A ball valve can be installed at any angle. A swing or lift check valve has to be mounted so gravity or the spring can close it, and installing one on a downward vertical line is the most common check valve mistake we see.
- Failure mode. A ball valve fails the way it was left, open or shut. A check valve fails by leaking back or by sticking, and you usually find out when the pump reverses or a tank drains overnight.
The naming trap: a ball check valve is not a ball valve
This one causes real ordering mistakes. A ball check valve is a check valve that uses a loose ball as its closing element. A ball valve uses a fixed ball on a stem that you rotate. They share a word and nothing else, so if a spec sheet says “ball valve” on a pump discharge, ask whether they mean isolation or non-return before you buy.
Where each belongs in a real system
The clearest example is a pump discharge line, because it needs both.
Directly after the pump goes the check valve. When the pump stops, the column of water above it wants to run back through the impeller, spinning it in reverse and draining the line. The check valve shuts and holds that column in place. Downstream goes the ball valve. Its job is isolation: shut it and you can pull the pump or the check valve for service without draining the system.
On long or vertical discharge lines the check valve type matters. A swing check that slams shut when a big column of water reverses causes water hammer, which cracks fittings and loosens flanges over time. A spring-assisted dual plate check closes before flow fully reverses, which is why it is the usual recommendation for larger pump discharges.
Which one do you need?
Ask three questions:
- Will someone need to shut this line on purpose, for maintenance, safety or process reasons? Then you need a ball valve.
- Is there anything upstream that would be damaged, contaminated or drained if flow ran backwards, such as a pump, a compressor, a tank or a potable water supply? Then you need a check valve.
- Both? Then you need both, and the check valve goes nearer the equipment it is protecting.
Browse our stainless steel ball valves and our check valve range online, or call 1300 VALVES (825 837) with your line size, media and pressure and we will tell you which to fit and where.
Frequently Asked Questions
Can I use a ball valve instead of a check valve?
Only if someone is standing there to shut it the instant flow stops, which is not realistic. A ball valve does nothing on its own, so it cannot stop backflow when a pump trips at 2 am. If the risk is reverse flow, fit a check valve. If you also need to isolate the line for maintenance, fit a ball valve as well. They are not interchangeable.
Do I still need a check valve if I already have a ball valve on the pump?
Yes, if the pump is lifting water or pushing into a pressurised header. The ball valve protects the pump only when someone has closed it. The check valve protects it every time the pump stops. Without one, the discharge column runs back through the impeller, the pump spins in reverse and the line loses prime. Both valves on a pump discharge is standard practice, not over-engineering.
Can a check valve be installed vertically?
It depends on the type. Swing checks and most lift checks work on horizontal lines and on vertical lines where flow travels upward, because gravity helps close them. Fit one on a downward vertical line and the disc may hang open. Spring-loaded dual plate and spring-assisted lift checks work in any orientation. Check the arrow on the body and the datasheet before installing, and if in doubt call us on 1300 VALVES.
About the Author
Just Valves is an Australian-owned industrial valve supplier headquartered in Bibra Lake, Western Australia. The team specifies, supplies and repairs valves for mining, oil and gas, water and process customers across Australia, with in-house capability covering valve selection, actuation, repair and overhaul. This article was prepared by the Just Valves technical team.