Technical References

End Connections

A practical guide to common valve end connections, what they mean, when they are used, and what to check before selecting or ordering a valve.

OVERVIEW

Overview

The end connection is the part of the valve that physically joins to the pipework. It may be threaded, flanged, welded, clamped, wafer-style, lugged, or connected to instrument tubing. The correct connection type affects installation, pressure capability, leakage risk, maintenance, and whether the valve can be removed later without cutting the pipe.

Connection type
How the valve attaches to the pipeline or tubing.
Application fit
Chosen based on pressure, size, media, service duty, and maintenance needs.
Compatibility
The valve connection must match the pipe, flange, thread, tube, gasket, and site standard.

Important: A valve can be the correct size but still have the wrong end connection. Always confirm the thread type, flange standard, welding end, tube OD, pressure class, and any site specification before ordering.

Why End Connections Matter

  • They determine whether the valve will physically fit the existing pipework.
  • They affect how easy the valve is to install, remove, service, or replace.
  • They influence leakage risk, especially in high-pressure, steam, gas, chemical, or hazardous service.
  • They must match the site standard, such as BSP, NPT, AS 4087, ANSI / ASME, DIN, Tri-Clamp, or tube OD fittings.

Common Valve End Connections

Connection Type Simple Description Typical Size Range When to Use
Screwed BSP British Standard Pipe thread. Can be BSPT tapered or BSPP parallel. DN8 to DN100 Most common small bore thread type in Australia. Used for water, air, general service, plumbing, and many industrial valves.
Screwed NPT National Pipe Taper thread. US tapered thread form. DN8 to DN100 Common on US equipment, oil and gas instruments, imported skids, and API-style equipment.
Flanged Bolted between matching pipe flanges using bolts and a gasket. DN15 to DN1200+ Used for larger pipework, higher loads, process plant, water systems, and valves that need to be removable.
Butt Weld Valve is welded directly to the pipe with a full weld joint. DN15 to DN600+ Used where a permanent, strong, leak-resistant joint is required, especially high pressure, high temperature, or critical service.
Socket Weld Pipe fits into a socket in the valve and is fillet welded around the outside. DN15 to DN100 Used for high-pressure small bore pipework where threaded joints are not preferred.
Wafer Valve is clamped between two pipeline flanges. The valve usually has no full end flanges of its own. DN50 to DN1200+ Common for butterfly valves and wafer check valves. Compact, lightweight, and cost-effective.
Lugged Wafer Similar to wafer style, but with threaded lugs around the valve body. DN50 to DN1200+ Useful where one side of the pipe may need to be removed. Can suit some dead-end service depending on valve design and rating.
Compression / Tube Ferrule-style connection that seals onto the outside diameter of tube. Tube sizes approx. 1/8 in to 2 in Common for instrumentation, hydraulics, laboratories, sampling systems, and analytical equipment.
Tri-Clamp / Sanitary Clamp Hygienic clamp connection using a gasket and clamp. DN15 to DN150 Used in food, beverage, pharmaceutical, dairy, and hygienic process applications.
Grooved Mechanical grooved pipe coupling connection. DN25 to DN300+ Common in fire protection, building services, mechanical pipework, and quick-install systems.

Thread warning: BSP and NPT threads are not interchangeable. They have different thread forms and angles, so mixing them can cause poor engagement, leakage, or thread damage. Always confirm the exact thread type before ordering.

Threaded Connections: BSP vs NPT

Threaded valves are common in small bore pipework because they are quick to install and usually cost less than flanged or welded valves. The main risk is assuming all threads are the same.

Thread Type What It Means Common Use Key Check
BSPT British Standard Pipe Taper thread. The thread seals by tightening into the mating thread, often with sealant or tape. Common in Australian pipework. Confirm BSPT male/female and suitable sealant.
BSPP British Standard Pipe Parallel thread. Usually seals using a washer, bonded seal, O-ring, or gasket face rather than thread taper alone. Instruments, equipment ports, hydraulic fittings, and some valve connections. Confirm whether a face seal or washer is required.
NPT National Pipe Taper thread. Common US tapered pipe thread. US equipment, oil and gas, imported machinery, and some instrumentation. Do not force into BSP fittings. Confirm NPT male/female.

Flanged Connections

A flanged valve is bolted into the pipeline between matching pipe flanges. A gasket sits between the flange faces to create the seal. Flanged valves are common on larger pipe sizes because they are strong, serviceable, and can usually be removed without cutting the pipe.

Basic understanding: For a flanged valve to fit correctly, the DN / NPS size, flange standard, pressure class, bolt hole pattern, face type, gasket type, and pressure-temperature rating must suit the existing pipework.

Flange Detail Why It Matters
Flange standard Examples include AS 4087, AS/NZS 4331, ANSI / ASME B16.5, DIN / EN, and BS 10. Different standards can have different drilling patterns.
Pressure class Examples include PN16, PN40, Class 150, Class 300, Table D, Table E. This affects pressure capability and dimensions.
PCD and bolt holes The bolt circle and holes must match the mating flange. Same DN size does not guarantee compatibility.
Face type Raised Face, Flat Face, or RTJ face must suit the gasket and mating flange.
Gasket type The gasket material and shape must suit the media, pressure, temperature, and flange face.

Wafer and Lugged Valves

Wafer and lugged valves are most commonly seen with butterfly valves and check valves. They are installed between two pipe flanges, but they are usually more compact than fully flanged valves.

Style Simple Explanation Main Advantage Important Check
Wafer Valve is held in place by the bolts passing around or through the valve and clamping it between two flanges. Compact, lightweight, and usually lower cost. Requires compatible flanges on both sides. Check centring, gasket suitability, and disc clearance.
Lugged Valve body has lugs with threaded holes for bolts. Can allow one side of the pipe to be removed in some installations. Check whether the valve is rated for dead-end service and at what pressure.

Welded Connections

Welded valve connections are used where a stronger or more permanent joint is required. They reduce the number of mechanical joints, but they are harder to remove later because the valve is welded into the line.

Connection Best For Practical Note
Butt weld Critical, high-pressure, high-temperature, steam, gas, chemical, and process service. Provides a strong welded joint, but valve removal usually requires cutting the pipe.
Socket weld High-pressure small bore pipework, especially where screwed joints are not suitable. Common in smaller sizes. Welding procedure and material compatibility should be checked.

Welding note: For welded valves, confirm the valve material, pipe material, welding procedure, heat treatment requirements, and whether soft seats or seals need protection during welding.

Compression and Sanitary Connections

Connection What It Is Common Use Important Check
Compression / Tube A fitting that seals onto tube OD using ferrules or compression rings. Instrumentation, hydraulic lines, sampling lines, and laboratory systems. Confirm tube outside diameter, fitting brand/style, material, and pressure rating.
Tri-Clamp / Sanitary A hygienic clamp joint with a gasket between two ferrules. Food, beverage, dairy, pharmaceutical, and clean process lines. Confirm size standard, gasket material, surface finish, and hygienic requirements.

Quick Selection Checklist

Before selecting or quoting a valve, confirm the following details:

Check What to Confirm
Pipe / valve size DN or NPS size, and whether full bore or reduced bore matters.
Connection type BSP, NPT, flanged, wafer, lugged, welded, compression, Tri-Clamp, grooved, etc.
Pressure class PN rating, ANSI / ASME Class, AS 2129 Table, AS 4087 class, or site requirement.
Media and temperature Water, air, steam, gas, chemical, oil, slurry, food product, etc.
Material compatibility Body, trim, seat, seals, gasket, bolts, and coating if applicable.
Maintenance needs Does the valve need to be removable, serviceable, or suitable for dead-end operation?
Standard or specification Any project, site, mine, water authority, food-grade, oil and gas, or compliance requirements.
Installation conditions Indoor/outdoor, corrosive environment, vibration, pipe support, access, and orientation.

Common Mistakes to Avoid

  • Assuming BSP and NPT threads will fit together.
  • Ordering a flanged valve by DN size only without checking flange standard and drilling.
  • Using a wafer valve where dead-end service is required without checking the rating.
  • Selecting a welded valve without considering future maintenance or replacement.
  • Using the wrong gasket type for the flange face, media, pressure, or temperature.
  • Forgetting that imported equipment may use a different thread or flange standard from local pipework.

Need Help Confirming an End Connection?

Tell us about your valve and site. We’ll confirm scope, pricing, and lead time — usually same day. The more detail you provide, the faster we can quote.
Submit your question