Technical References

Leakage Classes

A simple guide to valve seat leakage classes, bubble-tight shut-off, and when to specify tighter leakage requirements.

OVERVIEW

Overview

Valve leakage class describes how much internal leakage is allowed past the valve seat when the valve is closed. It is mainly used for control valves, but it is also helpful when discussing tight shut-off requirements for isolation valves such as ball, butterfly, gate, and plug valves.

Seat leakage
Leakage through the closed valve, from the inlet side to the outlet side. This is different from external leakage to atmosphere.
Leakage class
A reference level that defines the maximum acceptable internal leakage during a standard test.
Bubble-tight
A common term for very tight shut-off, usually associated with soft seats and Class VI testing.

Important: A leakage class does not make a valve suitable by itself. Always check valve type, seat material, pressure, temperature, media, operating direction, and the manufacturer data sheet.

What Does Internal Seat Leakage Mean?

When a valve is closed, the seat is the sealing area that stops flow passing through the valve. Some valve designs allow a small amount of leakage, especially metal-seated control valves. Other valves, such as soft-seated ball valves, are designed for much tighter shut-off.

  • Internal leakage means fluid passing through the valve even though the valve is closed.
  • External leakage means fluid leaking out of the valve body, bonnet, stem, gland, or end connection.
  • Leakage class normally refers to internal seat leakage, not external leakage.

Basic example: A control valve used for throttling steam may allow a small amount of leakage when closed. A soft-seated isolation valve used to shut off water or air is normally expected to seal much more tightly.

ANSI / FCI 70-2 Leakage Classes

ANSI / FCI 70-2 is one of the most common references for control valve seat leakage. The classes range from Class I to Class VI. Lower classes allow more leakage. Higher classes require tighter shut-off.

Class Simple meaning Test medium Typical use
Class I No standard leakage test required Usually not specified Metal-to-metal seated control valves where leakage is acceptable.
Class II Up to 0.5% of rated Cv Air or water at test pressure Older or double-port control valves where some leakage is acceptable.
Class III Up to 0.1% of rated Cv Air or water at test pressure General metal-seated throttling/control service.
Class IV Up to 0.01% of rated Cv Air or water at test pressure Common class for modern single-seat metal-seated control valves.
Class V Very tight leakage limit based on pressure differential Water at maximum rated differential pressure High shut-off requirement, often for severe service or special metal-seated valves.
Class VI Bubble-tight style test, measured by bubbles per minute Air or nitrogen at specified test pressure Soft-seated valves and applications requiring very tight shut-off.

Simple rule: Class IV is common for metal-seated control valves. Class V is very tight. Class VI is normally used where bubble-tight shut-off is required.

Control Valves vs Isolation Valves

Leakage class is most often used for control valves because many control valves are designed to regulate flow rather than provide perfect shut-off. Isolation valves are normally selected to stop flow, so the expected shut-off performance can be different.

Valve type Typical expectation Notes
Control valve May allow limited seat leakage depending on class Specify the leakage class when shut-off performance is important.
Soft-seated ball valve Usually very tight shut-off PTFE, RPTFE, elastomer, or other soft seats are commonly used for tight shut-off.
Metal-seated ball valve Usually not bubble-tight unless specially designed/tested Often used for high temperature, abrasive, or severe service.
Butterfly valve Depends on seat design Resilient seated butterfly valves can be tight shut-off. Metal-seated and triple offset designs should be checked by data sheet.
Gate / globe valve Depends on seat material and design Metal seated designs may allow some leakage unless a tight shut-off requirement is specified.

When Should You Specify Class VI?

Class VI should be specified when the application needs very tight shut-off and even a small amount of leakage could cause a problem. It is commonly associated with soft-seated valves, but the actual guarantee must come from the valve manufacturer.

  • When the valve must provide tight shut-off between two parts of the system.
  • When leakage could cause contamination, product loss, safety issues, or process problems.
  • When the customer or project specification specifically asks for Class VI or bubble-tight shut-off.
  • When selecting solenoid valves, soft-seated ball valves, or control valves for shut-off service.

Important wording: Avoid saying “zero leakage” unless the manufacturer specifically guarantees it. In many standards and valve applications, the safer wording is “Class VI shut-off”, “bubble-tight shut-off”, or “tight shut-off as per manufacturer test standard”.

Seat Material and Leakage Performance

The seat material has a major effect on how tightly a valve can shut off. Soft seats generally seal more tightly, while metal seats are better for high temperature, abrasive, or severe service but may allow more leakage.

Seat type Typical shut-off Common use
Soft seat Very tight shut-off, often suitable for Class VI Water, air, gas, chemicals, general process, clean service.
Metal seat Usually Class IV or Class V depending on design Steam, high temperature, abrasive service, dirty fluids, severe service.
Elastomer seat Very tight shut-off when compatible with the media Butterfly valves, diaphragm valves, water, air, and selected chemical service.
PTFE / RPTFE seat Very common tight shut-off seat material Ball valves, plug valves, chemical service, clean fluids.

Information to Confirm Before Quoting

Before promising a leakage class, confirm the full application details and check the manufacturer data sheet or test certificate requirements.

Valve type
Control valve, ball valve, butterfly valve, gate valve, globe valve, solenoid valve, or other design.
Seat material
Soft seat, metal seat, PTFE, elastomer, or other sealing material.
Service conditions
Media, pressure, temperature, pressure differential, flow direction, and whether the media is clean or dirty.
Required standard
ANSI / FCI 70-2, API, MSS, ISO, project specification, or manufacturer standard.
Test certificate
Whether the customer requires a test report, certificate, or witness testing.
Shut-off wording
Use clear wording such as Class VI, bubble-tight, tight shut-off, or manufacturer standard.

Common Mistakes to Avoid

  • Assuming every valve is bubble-tight just because it is new.
  • Confusing internal seat leakage with external leakage from the stem or body.
  • Specifying Class VI for a metal-seated high-temperature valve without confirming availability.
  • Using the term “zero leakage” without a manufacturer guarantee or test standard.
  • Forgetting that pressure, temperature, media, and seat material can change leakage performance.

Simple rule of thumb: For normal tight shut-off, confirm the valve design and seat material. For a project-specified leakage requirement, state the exact leakage class and test standard on the quote or order.

Need Help Confirming Leakage Class?

Tell us about your valve and site. We’ll confirm scope, pricing, and lead time — usually same day. The more detail you provide, the faster we can quote.
Submit your question