Technical References

Mesh & Screen Sizing

A simple guide to strainer mesh sizes, screen apertures, particle retention, pressure drop, and how to choose a suitable screen size for common valve, pump, and process applications.

OVERVIEW

Overview

Strainers and filters protect downstream equipment by catching unwanted particles before they can enter pumps, valves, meters, nozzles, heat exchangers, and instruments. The screen or mesh inside the strainer has openings called apertures. Particles larger than the aperture are normally caught, while smaller particles can pass through.

Mesh number
How many openings there are per linear inch of mesh. A higher mesh number means more openings and a finer screen.
Aperture
The actual opening size in the screen, usually shown in millimetres or microns.
Microns
The unit used for very small openings. 1 millimetre equals 1,000 microns.

Important: A finer screen is not always better. Fine mesh catches smaller particles, but it can also create higher pressure drop and may need cleaning more often. The best screen size balances equipment protection with flow performance and maintenance.

What Mesh Size Means

Mesh number tells you how many openings there are per linear inch of mesh. A higher mesh number usually means a finer screen and a smaller opening. For example, 20 mesh is much coarser than 100 mesh.

Aperture is the actual opening size in the screen. Aperture is usually shown in millimetres or microns. This is often the most useful value when deciding what size particle the screen will stop.

Microns are used for very small openings. 1 millimetre equals 1,000 microns, so a 0.25 mm opening is the same as 250 microns.

Simple rule: Mesh number is the screen description. Aperture is the opening size. For selection, aperture is usually the more important number.

Mesh and Perforation Aperture Selection Guide

Use this table as a practical starting point when selecting a strainer or filter screen. The final selection should still consider the flow rate, pressure drop, solids loading, and the equipment being protected.

Aperture Mesh equivalent What it helps stop Common use Practical note
6 mm Coarse perforation Large debris, weld spatter, pipe scale Commissioning flushing, temporary cone strainers Remove temporary strainers after commissioning.
3 mm Coarse perforation Nuts, bolts, large particles Large pump suction lines, crude or dirty service Very coarse protection only.
2 mm Coarse perforation Coarse grit and stones Pump suction, irrigation, raw water intake Common coarse option for general dirty water.
1 mm Approx. 18 mesh Grit and coarse sand Pump and heat exchanger inlet protection Very common in water and process plant.
0.5 mm Approx. 32 mesh Sand and medium particles Control valves, instruments, pump protection Good general-purpose protection.
0.25 mm Approx. 60 mesh Fine sand and small scale Spray nozzles, flow meters, fine dosing May need regular cleaning.
0.15 mm Approx. 100 mesh Very fine particles Precision instruments and turbine meters Monitor pressure drop closely.
0.05 mm Approx. 270 mesh Very fine sediment and scale Analytical equipment and high-precision systems Usually suits dedicated filter housings, not basic strainers.

Mesh Size Comparison Chart

This comparison chart shows common mesh numbers and their approximate opening size in inches, microns, and millimetres. Values are approximate because the actual aperture can change depending on wire diameter and screen construction.

Mesh number Opening (inches) Opening (microns) Opening (mm)
3 0.265 6,730 6.73
4 0.187 4,760 4.76
5 0.157 4,000 4.00
6 0.132 3,360 3.36
7 0.111 2,830 2.83
8 0.0937 2,380 2.38
10 0.0787 2,000 2.00
12 0.0661 1,680 1.68
14 0.0555 1,410 1.41
16 0.0469 1,190 1.19
18 0.0394 1,000 1.00
20 0.0331 841 0.841
25 0.028 707 0.707
30 0.0232 595 0.595
35 0.0197 500 0.500
40 0.0165 400 0.400
45 0.0138 354 0.354
50 0.0117 297 0.297
60 0.0098 250 0.250
70 0.0083 210 0.210
80 0.007 177 0.177
100 0.0059 149 0.149
120 0.0049 125 0.125
140 0.0041 105 0.105
170 0.0035 88 0.088
200 0.0029 74 0.074
230 0.0024 63 0.063
270 0.0021 53 0.053
325 0.0017 44 0.044
400 0.0015 37 0.037

Note: Mesh and micron conversions are approximate. For critical applications, always confirm the actual screen aperture from the strainer or mesh manufacturer.

Screen Area and Pressure Drop Guidance

A clean strainer normally creates a small pressure drop. As the screen catches debris, the pressure drop increases. If the screen is too fine or too small for the flow rate, it may block quickly and reduce flow to the system.

Item Simple guidance Why it matters
Screen open area The open area of the screen should generally be larger than the pipe area. A common guide is 3 to 4 times the pipe bore area. More open area helps reduce pressure drop and extends cleaning intervals.
Clean pressure drop A correctly sized clean strainer commonly has a low pressure drop at design flow. The exact value depends on strainer design, mesh size, flow rate, and media.
Cleaning indicator Differential pressure gauges can be installed across the strainer. Clean the screen when pressure drop rises above the site limit or equipment requirement.
Duplex strainer A duplex strainer allows one basket to be cleaned while the other remains in service. Useful for continuous processes where shutdown is difficult.
Temporary strainer Cone and temporary strainers are normally for flushing and commissioning only. They should usually be removed after commissioning to avoid collapse or blockage.

How to Choose a Practical Screen Size

Application Selection approach Typical comment
Pump protection Start coarse enough to avoid frequent blockage, then check pump or equipment requirements. 1 to 3 mm is common for coarse protection; finer screens may be used where needed.
Control valves and instruments Use a finer screen where small particles could damage seats, trims, or small passages. 0.5 mm to 0.25 mm is a common starting range.
Spray nozzles and flow meters Small passages can block easily, so finer filtration may be required. Check the equipment manufacturer’s minimum filtration requirement.
Slurry or dirty water Do not select mesh too fine unless cleaning access and pressure drop are considered. A larger strainer body or coarse screen may be more practical.
Commissioning / flushing Use temporary protection to catch construction debris, weld spatter, and pipe scale. Remove or replace temporary strainers after flushing is complete.

Common Mistakes to Avoid

  • Selecting the finest mesh available without checking pressure drop.
  • Using a temporary cone strainer as a permanent strainer.
  • Ignoring cleaning access when the strainer is installed.
  • Not allowing enough screen area for dirty water or high solids loading.
  • Assuming mesh number alone confirms the exact aperture.
  • Forgetting to check the downstream equipment manufacturer’s filtration requirement.

Need help selecting a strainer screen?

Tell us about your valve and site. We’ll confirm scope, pricing, and lead time — usually same day. The more detail you provide, the faster we can quote.
Submit your question