A simple guide to strainer mesh sizes, screen apertures, particle retention, pressure drop, and how to choose a suitable screen size for common valve, pump, and process applications.
Strainers and filters protect downstream equipment by catching unwanted particles before they can enter pumps, valves, meters, nozzles, heat exchangers, and instruments. The screen or mesh inside the strainer has openings called apertures. Particles larger than the aperture are normally caught, while smaller particles can pass through.
Important: A finer screen is not always better. Fine mesh catches smaller particles, but it can also create higher pressure drop and may need cleaning more often. The best screen size balances equipment protection with flow performance and maintenance.
Mesh number tells you how many openings there are per linear inch of mesh. A higher mesh number usually means a finer screen and a smaller opening. For example, 20 mesh is much coarser than 100 mesh.
Aperture is the actual opening size in the screen. Aperture is usually shown in millimetres or microns. This is often the most useful value when deciding what size particle the screen will stop.
Microns are used for very small openings. 1 millimetre equals 1,000 microns, so a 0.25 mm opening is the same as 250 microns.
Simple rule: Mesh number is the screen description. Aperture is the opening size. For selection, aperture is usually the more important number.
Use this table as a practical starting point when selecting a strainer or filter screen. The final selection should still consider the flow rate, pressure drop, solids loading, and the equipment being protected.
| Aperture | Mesh equivalent | What it helps stop | Common use | Practical note |
|---|---|---|---|---|
| 6 mm | Coarse perforation | Large debris, weld spatter, pipe scale | Commissioning flushing, temporary cone strainers | Remove temporary strainers after commissioning. |
| 3 mm | Coarse perforation | Nuts, bolts, large particles | Large pump suction lines, crude or dirty service | Very coarse protection only. |
| 2 mm | Coarse perforation | Coarse grit and stones | Pump suction, irrigation, raw water intake | Common coarse option for general dirty water. |
| 1 mm | Approx. 18 mesh | Grit and coarse sand | Pump and heat exchanger inlet protection | Very common in water and process plant. |
| 0.5 mm | Approx. 32 mesh | Sand and medium particles | Control valves, instruments, pump protection | Good general-purpose protection. |
| 0.25 mm | Approx. 60 mesh | Fine sand and small scale | Spray nozzles, flow meters, fine dosing | May need regular cleaning. |
| 0.15 mm | Approx. 100 mesh | Very fine particles | Precision instruments and turbine meters | Monitor pressure drop closely. |
| 0.05 mm | Approx. 270 mesh | Very fine sediment and scale | Analytical equipment and high-precision systems | Usually suits dedicated filter housings, not basic strainers. |
This comparison chart shows common mesh numbers and their approximate opening size in inches, microns, and millimetres. Values are approximate because the actual aperture can change depending on wire diameter and screen construction.
| Mesh number | Opening (inches) | Opening (microns) | Opening (mm) |
|---|---|---|---|
| 3 | 0.265 | 6,730 | 6.73 |
| 4 | 0.187 | 4,760 | 4.76 |
| 5 | 0.157 | 4,000 | 4.00 |
| 6 | 0.132 | 3,360 | 3.36 |
| 7 | 0.111 | 2,830 | 2.83 |
| 8 | 0.0937 | 2,380 | 2.38 |
| 10 | 0.0787 | 2,000 | 2.00 |
| 12 | 0.0661 | 1,680 | 1.68 |
| 14 | 0.0555 | 1,410 | 1.41 |
| 16 | 0.0469 | 1,190 | 1.19 |
| 18 | 0.0394 | 1,000 | 1.00 |
| 20 | 0.0331 | 841 | 0.841 |
| 25 | 0.028 | 707 | 0.707 |
| 30 | 0.0232 | 595 | 0.595 |
| 35 | 0.0197 | 500 | 0.500 |
| 40 | 0.0165 | 400 | 0.400 |
| 45 | 0.0138 | 354 | 0.354 |
| 50 | 0.0117 | 297 | 0.297 |
| 60 | 0.0098 | 250 | 0.250 |
| 70 | 0.0083 | 210 | 0.210 |
| 80 | 0.007 | 177 | 0.177 |
| 100 | 0.0059 | 149 | 0.149 |
| 120 | 0.0049 | 125 | 0.125 |
| 140 | 0.0041 | 105 | 0.105 |
| 170 | 0.0035 | 88 | 0.088 |
| 200 | 0.0029 | 74 | 0.074 |
| 230 | 0.0024 | 63 | 0.063 |
| 270 | 0.0021 | 53 | 0.053 |
| 325 | 0.0017 | 44 | 0.044 |
| 400 | 0.0015 | 37 | 0.037 |
Note: Mesh and micron conversions are approximate. For critical applications, always confirm the actual screen aperture from the strainer or mesh manufacturer.
A clean strainer normally creates a small pressure drop. As the screen catches debris, the pressure drop increases. If the screen is too fine or too small for the flow rate, it may block quickly and reduce flow to the system.
| Item | Simple guidance | Why it matters |
|---|---|---|
| Screen open area | The open area of the screen should generally be larger than the pipe area. A common guide is 3 to 4 times the pipe bore area. | More open area helps reduce pressure drop and extends cleaning intervals. |
| Clean pressure drop | A correctly sized clean strainer commonly has a low pressure drop at design flow. | The exact value depends on strainer design, mesh size, flow rate, and media. |
| Cleaning indicator | Differential pressure gauges can be installed across the strainer. | Clean the screen when pressure drop rises above the site limit or equipment requirement. |
| Duplex strainer | A duplex strainer allows one basket to be cleaned while the other remains in service. | Useful for continuous processes where shutdown is difficult. |
| Temporary strainer | Cone and temporary strainers are normally for flushing and commissioning only. | They should usually be removed after commissioning to avoid collapse or blockage. |
| Application | Selection approach | Typical comment |
|---|---|---|
| Pump protection | Start coarse enough to avoid frequent blockage, then check pump or equipment requirements. | 1 to 3 mm is common for coarse protection; finer screens may be used where needed. |
| Control valves and instruments | Use a finer screen where small particles could damage seats, trims, or small passages. | 0.5 mm to 0.25 mm is a common starting range. |
| Spray nozzles and flow meters | Small passages can block easily, so finer filtration may be required. | Check the equipment manufacturer’s minimum filtration requirement. |
| Slurry or dirty water | Do not select mesh too fine unless cleaning access and pressure drop are considered. | A larger strainer body or coarse screen may be more practical. |
| Commissioning / flushing | Use temporary protection to catch construction debris, weld spatter, and pipe scale. | Remove or replace temporary strainers after flushing is complete. |