Technical References

Pressure-Temperature Ratings

A simple guide to how valve pressure ratings reduce as temperature increases, and why P-T tables must be checked for elevated-temperature service.

OVERVIEW

Overview

A valve pressure rating is not one fixed number for every temperature. Most ratings are quoted at a baseline temperature, often around room temperature. As the operating temperature increases, the allowable working pressure normally reduces because the valve material becomes weaker at higher temperatures.

Pressure rating
The maximum pressure a valve can safely handle under stated conditions.
Temperature effect
Higher temperature usually reduces the allowable pressure for the same valve.
P-T table
A pressure-temperature table shows the safe pressure limit at different temperatures.

Important: Do not select a valve using only the pressure class printed on the body. For hot water, steam, thermal oil, or high-temperature process service, always check the pressure-temperature rating for the exact material and standard.

Why Does Pressure Rating Reduce at Higher Temperature?

Valve bodies, bonnets, bolting, seats, and seals all have temperature limits. At higher temperatures, metallic materials can lose strength and soft seat materials can also lose sealing performance. This means a valve that is acceptable at room temperature may not be suitable at the same pressure when the service is hot.

  • The material strength reduces as temperature increases.
  • Seats, seals, gaskets, and packing may have lower temperature limits than the body material.
  • Steam and thermal oil applications need extra care because pressure and temperature are closely linked.
  • Different materials have different pressure-temperature curves, even in the same pressure class.

Basic example: A Class 150 carbon steel valve may be commonly associated with about 19.6 bar at low temperature. At 200°C, the allowable pressure is lower, so the full pressure-temperature table must be checked before quoting or installing.

Common Terms

Term Simple meaning Why it matters
Class 150 / 300 ASME / ANSI pressure class references. The class gives a pressure-rating family, but the allowable pressure still changes with material and temperature.
PN rating Metric pressure class reference, such as PN16 or PN40. Useful for flange and valve selection, but it is still subject to temperature and material limits.
WCB A common cast carbon steel valve body material. Often used in general process, steam, oil and gas, and industrial service.
Allowable pressure The maximum working pressure allowed at a stated temperature. This is the value to check when the service is above room temperature.
Design temperature The maximum temperature the system is designed to reach. Use this temperature when checking the valve rating, not just the normal operating temperature.

ASME B16.34 Class 150 - Carbon Steel WCB

The table below gives indicative Class 150 carbon steel WCB values. I have filled the notes column with short practical comments instead of leaving blank cells, so the table is easier to read and looks more complete.

Temperature Allowable pressure Practical note
-29°C to 38°C 19.6 bar Baseline low-temperature rating often quoted for Class 150.
50°C 19.2 bar Small reduction; usually close to the baseline rating.
100°C 17.7 bar Rating starts to reduce noticeably.
150°C 15.9 bar Derating continues; check if system pressure is close to this value.
200°C 14.8 bar Important for steam and hot process service.
250°C 13.8 bar Confirm valve body, trim, gasket, and packing suitability.
300°C 12.8 bar High-temperature service; check full B16.34 table.
350°C 11.7 bar Significant derating; confirm against manufacturer data.
400°C 10.2 bar Near upper practical range for many carbon steel applications.
425°C 9.3 bar Close to practical limit for WCB; specialist review recommended.

ASME B16.34 Class 300 - Carbon Steel WCB

Class 300 has a higher pressure capability than Class 150, but it still derates as temperature increases. The higher class does not remove the need to check the pressure-temperature table.

Temperature Allowable pressure Practical note
-29°C to 38°C 51.1 bar Baseline low-temperature rating for Class 300.
100°C 46.6 bar Reduced from baseline; still substantially higher than Class 150.
200°C 38.6 bar Important check point for steam and hot process service.
300°C 33.4 bar Confirm against full B16.34 table and manufacturer data.
400°C 26.8 bar Significant derating at elevated temperature.
425°C 24.3 bar Near upper practical range; confirm for final design.

Best table approach: For website or catalogue tables, avoid blank cells where possible. Use short entries such as “check datasheet”, “standard derating range”, “not usually specified”, or “confirm for final design”. This keeps the table tidy without pretending to provide extra certified data.

Steam Service Note

Steam service needs special attention because steam pressure and temperature are linked. The valve must be rated above the pressure required at the design temperature, and the valve materials, seats, gaskets, and packing must also be suitable for steam.

Steam check What to confirm
Saturation pressure Check the steam saturation pressure at the design temperature.
Valve P-T rating Confirm the allowable valve pressure at that same temperature.
Seat and packing Make sure the soft goods are suitable for steam temperature.
End connections Check flange class, thread type, gasket, bolting, and installation standard.

Example: Steam at 200°C has a saturation pressure of approximately 15.5 bar. A valve must be rated above the required pressure at 200°C, not just at room temperature.

How to Use a Pressure-Temperature Table

  • Confirm the valve material, such as WCB carbon steel, stainless steel, bronze, or duplex.
  • Confirm the pressure class, such as Class 150, Class 300, PN16, or PN40.
  • Find the design temperature, not only the normal operating temperature.
  • Read the allowable pressure at that temperature.
  • Check seats, seals, gaskets, packing, bolting, and end connections as well as the body rating.
  • For final design, use the full standard and manufacturer data sheet, not only an indicative guide.

Materials Can Have Different Curves

The values for carbon steel WCB are not automatically valid for stainless steel, duplex, bronze, cast iron, ductile iron, plastics, or special alloys. Each material and standard has its own limitations.

Carbon steel
Common for steam and process service, but must be checked at elevated temperature.
Stainless steel
Good corrosion resistance, but still has pressure-temperature limits.
Bronze / iron
Often used in water and general service; check face type, gasket and temperature suitability.
Plastic valves
Pressure ratings can reduce quickly with temperature.
Soft seats
PTFE, EPDM, NBR, Viton and other seats have their own temperature limits.
Certification
Critical applications may require test certificates or compliance to a project specification.

Common Mistakes to Avoid

  • Assuming Class 150 always means the same allowable pressure at every temperature.
  • Checking the body material but forgetting the seat, seal, gasket, packing or actuator temperature limit.
  • Using room-temperature ratings for steam, thermal oil, hot water or high-temperature process service.
  • Assuming PN16, Class 150, Table E or other flange references are all directly equivalent.
  • Using indicative tables for final engineering design without checking the applicable standard and manufacturer data sheet.

Need Help Checking a Pressure-Temperature Rating?

Tell us about your valve and site. We’ll confirm scope, pricing, and lead time — usually same day. The more detail you provide, the faster we can quote.
Submit your question